Table 14. Reason codes associated with step "VIRTMP", program code 008 (last revised 5/30/2001). NOTE: See the document "Summary of Virtual Temperature Processing in PREPBUFR" for more information. KEY: IN "R.CODE" COLUMN: B - OCCURS IN ALL OPERATIONAL VERSIONS OF VIRTMP EXCEPT RUC (THE VIRTMP STEP DOES NOT RUN IN THE RUC NETWORK). IN "MNEMONIC" COLUMN: # - NEW VALUE CALCULATED. R.CODE MEANING MNEMONICS AFFECTED AND NEW VALUE FOR OBS, Q.M. ====== ============================================== ============================================== 00 B SPECIFIC HUMIDITY OBSERVATION IS REGENERATED QRC-> QOB=# FROM REPORTED DEWPOINT TEMPERATURE AND PRESSURE. (DEWPOINT TEMPERATURE HAS UNDERGONE POSSIBLE CQC AND RADIATION CORRECTIONS). THIS IS VALID ONLY FOR SURFACE LAND OR MARINE DATA TYPES. 00 B TEMPERATURE OBSERVATION IS CONVERTED TO VIRTUAL TRC-> TOB=# TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE ABOVE) AND FROM A TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THIS IS VALID ONLY FOR SURFACE LAND OR MARINE DATA TYPES. 01 B SPECIFIC HUMIDITY OBSERVATION IS REGENERATED QRC-> QOB=# FROM REPORTED DEWPOINT TEMPERATURE AND PRESSURE. (DEWPOINT TEMPERATURE HAS UNDERGONE POSSIBLE CQC AND RADIATION CORRECTIONS). THIS IS VALID ONLY FOR RADIOSONDE, DROPWINSONDE, AND MULTI-LEVEL RECONNAISSANCE DATA TYPES. 01 B TEMPERATURE OBSERVATION IS CONVERTED TO TRC-> TOB=# VIRTUAL TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE ABOVE) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THIS IS VALID ONLY FOR RADIOSONDE, DROPWINSONDE, AND MULTI-LEVEL RECONNAISSANCE DATA TYPES. 02 B TEMPERATURE OBSERVATION IS CONVERTED TO TRC-> TOB=#, TQM=8 VIRTUAL TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE ABOVE) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THE SPECIFIC HUMIDITY HAS A REJECTED QUALITY MARKER. VIRTUAL TEMPERATURE IS CONSIDERED BAD. THIS IS VALID ONLY FOR SURFACE LAND OR MARINE DATA TYPES. 07 B TEMPERATURE OBSERVATION IS CONVERTED TO VIRTUAL TRC-> TOB=#, TQM=3 TEMPERATURE, CALCULATED FROM THE REGENERATED SPECIFIC HUMIDITY (SEE ABOVE) AND FROM A SENSIBLE TEMPERATURE OBSERVATION THAT HAS UNDERGONE POSSIBLE COMPLEX QUALITY CONTROL AND RADIATION CORRECTIONS. THE SPECIFIC HUMIDITY HAS A REJECTED QUALITY MARKER. THE PRESSURE LEVEL IS BELOW 700 MB AND THE SENSIBLE TEMPERATURE QUALITY MARKER IS EITHER 1, 2 OR 3. VIRTUAL TEMPERATURE IS CONSIDERED SUSPECT. THIS IS VALID ONLY FOR RADIOSONDE, DROPWINSONDE, AND MULTI-LEVEL RECONNAISSANCE DATA TYPES.